S-TF40R-D Tubular Heat Exchanger

S-TF40R-D Tubular Heat Exchanger Description
The S-TF40R-D Tubular Heat Exchanger is a shell and tube heat exchanger with annular space with removable inner tube and radial product inlet.
The S-TF40R-D Tubular Heat Exchanger is part of our new Sanitary Line.
S-TF40R-D Tubular Heat Exchanger Operation
The S-TF40R-D Tubular Heat Exchanger is a shell and tube heat exchanger consisting of three concentric tubes. The product flows through the central annular space while the service does it through the outer and inner channels.

S-TF40R-D Tubular Heat Exchangers Applications
Heating processes (pasteurization, sterilization, UHT, etc.) or cooling processes of products with high viscosity. The products may contain fibers or particles. This model is designed for products such as chocolates, butters, tomato paste, jams, pudding, custards, rice with milk, baby food and yogurt, among others.




S-TF40R-D Tubular Heat Exchanger Technical Data Sheet
Standard Design Conditions
Design Temperature: 180°C
Design Pressure: 10 barg
For higher design pressure or temperatures as well as hazardous fluids, the heat exchangers can be checked according to AD 2000 Merkblätt, ASME VIII Div.1, PD 5500, EN13445 or by Finite Elements Analysis and CE certificated by individual inspection modules.
Included: CE Marking according to 2014/68/UE.
Standard Measures
Shell side: 52 mm – 204 mm
Inner tubes: ≥ 16 mm
Lenght: 1-1,5-2-3-6 m
Other connections available on request.
Materials
Shell and tubes:
Stainless Steel 304 or 316L
Other materials available on request (2205, 2507, 254 SMO among others)
Surface Finish
External
External Polished
Internal
Product channel designed to promote CIP (Clean In Place)
Available Connections
Clamp
Flange
DIN 11851
Other connections available on request.
Options
Insulation
Mineral wool coated in 304 stainless steel metal sheet.
Frame
Stainless Steel 304.
The type and shape of the frame will be selected to fit the needs of each project. If required, equipment may be sloping for better drainage.
Interconnections
In case the equipment contains several units in series, SACOME can provide the interconnections for the product channel and the service channel.
SACOME TYPE DEFINITION
S-TF40R-D-0-76/52/35/16-6000-304/316L-H
S
Sanitary Line
TF40R
Annular space and radial product inlet.
D
Removable inner tube
0/1
Without / with expansion joint
76
Ø TUBE 3 (mm)
52
Ø TUBE 2 (mm)
35
Ø TUBE 1 (mm)
16
Ø TUBE 0 (mm)
6000
Nominal lenght (mm)
304
Shell side material
316L
Tube side material
H/S/P
Corrugation indicator (Hard/Soft/Plain)
New mathematical models applied to heat exchangers
Our study of “New mathematical models applied to heat exchangers” has been recognized as a “Research and Development Project”.
Loops of Purified Water (PW) and Water for Injection (WFI)
Heat Exchangers for loops of Purified Water (PW) and Water for Injection (WFI) in the pharmaceutical and biotechnology industries.
The importance of rheology in the design of food plants
The importance of rheology in the design of any processing plant is crucial since the sizing of many of the elements composing it is very dependent on this “resistance”, also taking special relevance with food products: heat exchangers, pipes, valves, pumps, mixers, etc.
Engineering, Design and Manufacturing of Tubular Heat Exchangers
Can we help you?
Our Technical Staff shall be delighted to provide you with detailed information