{"id":42970,"date":"2026-05-12T09:45:15","date_gmt":"2026-05-12T07:45:15","guid":{"rendered":"https:\/\/www.sacome.com\/improving-the-performance-of-a-waste-treatment-plant\/"},"modified":"2026-05-12T09:46:45","modified_gmt":"2026-05-12T07:46:45","slug":"improving-the-performance-of-a-waste-treatment-plant","status":"publish","type":"post","link":"https:\/\/www.sacome.com\/en\/improving-the-performance-of-a-waste-treatment-plant\/","title":{"rendered":"Improving the performance of a waste treatment plant"},"content":{"rendered":"<p><i><em>As biogas gains importance as an energy resource, the demands placed on the systems responsible for its treatment and conditioning also increase.<\/em><\/i><\/p>\n<p>A facility for the selective collection, recycling, and treatment of municipal waste contacted <b>SACOME<\/b> to <b>improve its biogas conditioning system<\/b>. The client had a tubular heat exchanger connected to a droplet separator tank, both supplied by another vendor, whose performance was not meeting expectations.<\/p>\n<p>After replicating the operating parameters of the existing equipment, <b>SACOME\u2019s technicians proposed a series of improvements to achieve the required performance<\/b>:<\/p>\n<p>Increasing the heat exchange surface area by lengthening the inner tubes while ensuring that the pressure drop in the biogas did not become excessive.<\/p>\n<p>Resizing the glycol water inlet and outlet connections in the housing, as the existing diameter limited the heat exchange capacity.<\/p>\n<p>Incorporation of a metal expansion joint in the exchanger housing. Absent in the previous unit, it absorbs the differential expansions between the biogas and the glycol water during start-up and shutdown cycles, thereby protecting the tube-to-plate welds.<\/p>\n<p>Increase in the height of the droplet separator to improve condensation and better adapt its volume to the actual needs of the application.<\/p>\n<p>Thanks to SACOME\u2019s experience in biogas treatment using <a href=\"https:\/\/www.sacome.com\/intercambiador-industrial-multitubo\/\">I-TFM-I tubular heat exchangers<\/a>, the proposed new design does meet the customer\u2019s requirements.<\/p>\n<p><b><strong>Improving performance also means knowing where to act.<\/strong><\/b><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-42957\" src=\"https:\/\/www.sacome.com\/wp-content\/uploads\/2026\/05\/DSC03868-scaled.jpg\" alt=\"\" width=\"603\" height=\"1073\" srcset=\"https:\/\/www.sacome.com\/wp-content\/uploads\/2026\/05\/DSC03868-scaled.jpg 1439w, https:\/\/www.sacome.com\/wp-content\/uploads\/2026\/05\/DSC03868-169x300.jpg 169w, https:\/\/www.sacome.com\/wp-content\/uploads\/2026\/05\/DSC03868-576x1024.jpg 576w, https:\/\/www.sacome.com\/wp-content\/uploads\/2026\/05\/DSC03868-768x1366.jpg 768w, https:\/\/www.sacome.com\/wp-content\/uploads\/2026\/05\/DSC03868-863x1536.jpg 863w, https:\/\/www.sacome.com\/wp-content\/uploads\/2026\/05\/DSC03868-1151x2048.jpg 1151w, https:\/\/www.sacome.com\/wp-content\/uploads\/2026\/05\/DSC03868-1080x1921.jpg 1080w\" sizes=\"(max-width: 603px) 100vw, 603px\" \/><\/p>\n","protected":false},"excerpt":{"rendered":"<p>A municipal waste treatment plant contacted SACOME to improve the performance of its biogas conditioning system.<\/p>\n","protected":false},"author":2,"featured_media":42965,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[47],"tags":[149,90],"class_list":["post-42970","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news","tag-biogas-en","tag-heat-exchanger"],"_links":{"self":[{"href":"https:\/\/www.sacome.com\/en\/wp-json\/wp\/v2\/posts\/42970"}],"collection":[{"href":"https:\/\/www.sacome.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.sacome.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.sacome.com\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.sacome.com\/en\/wp-json\/wp\/v2\/comments?post=42970"}],"version-history":[{"count":1,"href":"https:\/\/www.sacome.com\/en\/wp-json\/wp\/v2\/posts\/42970\/revisions"}],"predecessor-version":[{"id":42978,"href":"https:\/\/www.sacome.com\/en\/wp-json\/wp\/v2\/posts\/42970\/revisions\/42978"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.sacome.com\/en\/wp-json\/wp\/v2\/media\/42965"}],"wp:attachment":[{"href":"https:\/\/www.sacome.com\/en\/wp-json\/wp\/v2\/media?parent=42970"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.sacome.com\/en\/wp-json\/wp\/v2\/categories?post=42970"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.sacome.com\/en\/wp-json\/wp\/v2\/tags?post=42970"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}