{"id":32135,"date":"2021-05-24T11:06:05","date_gmt":"2021-05-24T09:06:05","guid":{"rendered":"https:\/\/www.sacome.com\/?p=32135"},"modified":"2021-05-24T12:21:14","modified_gmt":"2021-05-24T10:21:14","slug":"continuous-cooling-volatile-liquid-products","status":"publish","type":"post","link":"https:\/\/www.sacome.com\/en\/continuous-cooling-volatile-liquid-products\/","title":{"rendered":"Cooling of different volatile liquid products"},"content":{"rendered":"<p>[et_pb_section bb_built=&#8221;1&#8243; fullwidth=&#8221;off&#8221; specialty=&#8221;off&#8221; next_background_color=&#8221;#000000&#8243;][et_pb_row][et_pb_column type=&#8221;1_5&#8243;][\/et_pb_column][et_pb_column type=&#8221;3_5&#8243;][et_pb_image src=&#8221;https:\/\/www.sacome.com\/wp-content\/uploads\/2021\/05\/Intercambiador-para-enfriamiento-de-diferentes-productos-liquidos-volatiles.jpg&#8221; alt=&#8221;Tubular heat exchanger intended for the continuous cooling of different volatile liquid products. &#8221; title_text=&#8221;Continuous cooling of different volatile liquid products&#8221; _builder_version=&#8221;3.21&#8243; align=&#8221;center&#8221; \/][\/et_pb_column][et_pb_column type=&#8221;1_5&#8243;][\/et_pb_column][\/et_pb_row][et_pb_row][et_pb_column type=&#8221;4_4&#8243;][et_pb_text _builder_version=&#8221;3.21&#8243; border_style=&#8221;solid&#8221;]<\/p>\n<h2>Heat exchanger intended for the continuous cooling of 5 m\u00b3\/h of different volatile liquid products.<\/h2>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;3.21&#8243; border_style=&#8221;solid&#8221;]<\/p>\n<p style=\"text-align: justify;\">An engineering company \u2014 specialized in <strong>processes for the pharmaceutical industry<\/strong> \u2014 has contacted <strong>SACOME<\/strong> to try to resolve the following enquiry. One of its clients need to expand its production capacity, due to a new supply contract for its products, but does not have the time necessary to face the construction of a new production space in the plant. The objective of this client is <strong>to install the new equipment in the existing plant, with short delivery time<\/strong>.<\/p>\n<p style=\"text-align: justify;\">One of the most critical equipment is the <strong>tubular heat exchanger intended for the continuous cooling of 5 m\u00b3\/h of different volatile liquid products<\/strong>. The client needs to maintain the design of the existing <strong>tubular heat exchanger<\/strong> \u2014 <strong>tube-in-tube heat exchanger (with concentric tubes)<\/strong>. But the engineering company is struggling to find a supplier capable to guarantee the new process, with the space constraints imposed.<\/p>\n<p style=\"text-align: justify;\">SACOME&#8217;s technical department has proposed an <strong>original solution that allows reaching the necessary exchange rate, ensuring self-draining, without taking up useful space on the floor<\/strong>. SACOME has <strong><a href=\"https:\/\/www.sacome.com\/en\/engineering-design\/\" rel=\"noopener\" target=\"_blank\">designed<\/a><\/strong> and <strong><a href=\"https:\/\/www.sacome.com\/en\/manufacturing\/\" rel=\"noopener\" target=\"_blank\">manufactured<\/a><\/strong> a <strong>frame with 9 tubular heat exchangers of 3 meter mounted in series, installed on the ceiling and with double inclination (units inclined to each other and inclined arrangement with respect to the horizontal)<\/strong>. With this design, <strong><a href=\"https:\/\/www.sacome.com\/en\/about-sacome\/\" rel=\"noopener\" target=\"_blank\">SACOME<\/a><\/strong> has solved the problem. Therefore, SACOME is awarded the supply of the <strong><a href=\"https:\/\/www.sacome.com\/en\/tube-in-tube-pharmaceutical-heat-exchanger\/\" rel=\"noopener\" target=\"_blank\">P-TF20-I heat exchangers<\/a><\/strong>.<\/p>\n<p>[\/et_pb_text][\/et_pb_column][\/et_pb_row][\/et_pb_section][et_pb_section bb_built=&#8221;1&#8243; _builder_version=&#8221;3.0.47&#8243; prev_background_color=&#8221;#000000&#8243;][et_pb_row _builder_version=&#8221;3.0.48&#8243; background_size=&#8221;initial&#8221; background_position=&#8221;top_left&#8221; background_repeat=&#8221;repeat&#8221;][et_pb_column type=&#8221;4_4&#8243;][et_pb_text _builder_version=&#8221;3.21&#8243; text_orientation=&#8221;center&#8221;]<\/p>\n<h3>Technical documentation heat exchangers<\/h3>\n<p>[\/et_pb_text][et_pb_blog fullwidth=&#8221;off&#8221; posts_number=&#8221;3&#8243; include_categories=&#8221;33&#8243; show_author=&#8221;off&#8221; show_date=&#8221;off&#8221; show_pagination=&#8221;off&#8221; use_overlay=&#8221;on&#8221; overlay_icon_color=&#8221;rgba(53,120,155,0.55)&#8221; _builder_version=&#8221;3.17.6&#8243; header_level=&#8221;h3&#8243; \/][\/et_pb_column][\/et_pb_row][\/et_pb_section]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Tubular heat exchanger intended for the continuous cooling of 5 m\u00b3\/h of different volatile liquid products for the pharmaceutical industry.<\/p>\n","protected":false},"author":2,"featured_media":32130,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[47],"tags":[],"class_list":["post-32135","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news"],"_links":{"self":[{"href":"https:\/\/www.sacome.com\/en\/wp-json\/wp\/v2\/posts\/32135"}],"collection":[{"href":"https:\/\/www.sacome.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.sacome.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.sacome.com\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.sacome.com\/en\/wp-json\/wp\/v2\/comments?post=32135"}],"version-history":[{"count":7,"href":"https:\/\/www.sacome.com\/en\/wp-json\/wp\/v2\/posts\/32135\/revisions"}],"predecessor-version":[{"id":32144,"href":"https:\/\/www.sacome.com\/en\/wp-json\/wp\/v2\/posts\/32135\/revisions\/32144"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.sacome.com\/en\/wp-json\/wp\/v2\/media\/32130"}],"wp:attachment":[{"href":"https:\/\/www.sacome.com\/en\/wp-json\/wp\/v2\/media?parent=32135"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.sacome.com\/en\/wp-json\/wp\/v2\/categories?post=32135"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.sacome.com\/en\/wp-json\/wp\/v2\/tags?post=32135"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}