{"id":32073,"date":"2021-05-10T11:29:39","date_gmt":"2021-05-10T09:29:39","guid":{"rendered":"https:\/\/www.sacome.com\/?p=32073"},"modified":"2021-05-10T12:45:32","modified_gmt":"2021-05-10T10:45:32","slug":"heat-exchangers-smokes-cooling-wastewater-treatment","status":"publish","type":"post","link":"https:\/\/www.sacome.com\/en\/heat-exchangers-smokes-cooling-wastewater-treatment\/","title":{"rendered":"Smoke cooling in a wastewater treatment plant (WWTP)"},"content":{"rendered":"<p>[et_pb_section bb_built=&#8221;1&#8243; fullwidth=&#8221;off&#8221; specialty=&#8221;off&#8221; next_background_color=&#8221;#000000&#8243;][et_pb_row][et_pb_column type=&#8221;4_4&#8243;][et_pb_text _builder_version=&#8221;3.21&#8243; border_style=&#8221;solid&#8221;]<\/p>\n<h2>Heat exchangers intended for the smokes cooling in the cogeneration system of a wastewater treatment plant.<\/h2>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;3.21&#8243; border_style=&#8221;solid&#8221;]<\/p>\n<p style=\"text-align: justify;\"><strong><a href=\"https:\/\/www.sacome.com\/en\/about-sacome\/\" rel=\"noopener\" target=\"_blank\">SACOME<\/a><\/strong> has been awarded a new contract for the <strong><a href=\"https:\/\/www.sacome.com\/en\/engineering-design\/\" rel=\"noopener\" target=\"_blank\">redesign<\/a><\/strong> and <strong><a href=\"https:\/\/www.sacome.com\/en\/manufacturing\/\" rel=\"noopener\" target=\"_blank\">manufacturing<\/a><\/strong> of two <strong><a href=\"https:\/\/www.sacome.com\/en\/multitube-industrial-heat-exchanger\/\" rel=\"noopener\" target=\"_blank\">I-TFM-I tubular heat exchangers<\/a><\/strong> to replace two existing heat exchangers in a <strong>wastewater treatment plant (WWTP)<\/strong>. The current heat exchangers are intended for the <strong>cooling of smokes from the cogeneration system<\/strong>, using <strong>process water<\/strong>, with an <strong>exchange power per unit of 100 kW<\/strong>. Due to an inadequate design of these heat exchangers, the system has continuous obstructions in the smoke channel, due to the dragging and deposition of the particles present and breaks in the tube-plate welds that force them to blind the tubes, with the consequent loss of exchange surface and performance.<\/p>\n<p>[\/et_pb_text][\/et_pb_column][\/et_pb_row][et_pb_row][et_pb_column type=&#8221;1_3&#8243;][\/et_pb_column][et_pb_column type=&#8221;1_3&#8243;][et_pb_image _builder_version=&#8221;3.21&#8243; src=&#8221;https:\/\/www.sacome.com\/wp-content\/uploads\/2021\/05\/Obstrucciones-en-el-canal-de-humos-de-una-EDAR.jpg&#8221; alt=&#8221;Heat exchangers intended for the smokes cooling in the cogeneration system of a wastewaster treatment plant.&#8221; title_text=&#8221;Obstruction in the smoke channel &#8221; \/][\/et_pb_column][et_pb_column type=&#8221;1_3&#8243;][\/et_pb_column][\/et_pb_row][et_pb_row][et_pb_column type=&#8221;4_4&#8243;][et_pb_text _builder_version=&#8221;3.21&#8243; border_style=&#8221;solid&#8221;]<\/p>\n<p style=\"text-align: justify;\">After analyzing the problem, <strong>SACOME&#8217;s technical department has proposed a redesign that provides a solution to the current heat exchangers problems<\/strong>. Among other improvements, the following matters are proposed:<\/p>\n<ul>\n<li>The modification of the existing heads, with a <strong>design without dead zones<\/strong> that avoids the accumulation of residues.<\/li>\n<li><strong>Changes in diameter and thickness for the inner tubes<\/strong>, to facilitate <strong>easy cleaning by mechanical means<\/strong>, if necessary.<\/li>\n<li><strong>Change of construction material<\/strong>, both in the channel in contact with the smokes and in the channel in contact with the service water.<\/li>\n<\/ul>\n<p>[\/et_pb_text][\/et_pb_column][\/et_pb_row][et_pb_row][et_pb_column type=&#8221;1_4&#8243;][\/et_pb_column][et_pb_column type=&#8221;1_2&#8243;][et_pb_image _builder_version=&#8221;3.21&#8243; src=&#8221;https:\/\/www.sacome.com\/wp-content\/uploads\/2021\/05\/Intercambiadores-tubulares-para-el-enfriamiento-de-los-humos-de-una-EDAR.jpg&#8221; alt=&#8221;Heat exchangers intended for the smokes cooling in the cogeneration system of a wastewaster treatment plant.&#8221; title_text=&#8221;Heat exchangers intended for the smokes cooling in the cogeneration system of a wastewaster treatment plant.&#8221; \/][\/et_pb_column][et_pb_column type=&#8221;1_4&#8243;][\/et_pb_column][\/et_pb_row][\/et_pb_section][et_pb_section bb_built=&#8221;1&#8243; _builder_version=&#8221;3.0.47&#8243; prev_background_color=&#8221;#000000&#8243;][et_pb_row _builder_version=&#8221;3.0.48&#8243; background_size=&#8221;initial&#8221; background_position=&#8221;top_left&#8221; background_repeat=&#8221;repeat&#8221;][et_pb_column type=&#8221;4_4&#8243;][et_pb_text _builder_version=&#8221;3.21&#8243; text_orientation=&#8221;center&#8221;]<\/p>\n<h3>Heat exchangers technical documentation<\/h3>\n<p>[\/et_pb_text][et_pb_blog fullwidth=&#8221;off&#8221; posts_number=&#8221;3&#8243; include_categories=&#8221;33&#8243; show_author=&#8221;off&#8221; show_date=&#8221;off&#8221; show_pagination=&#8221;off&#8221; use_overlay=&#8221;on&#8221; overlay_icon_color=&#8221;rgba(53,120,155,0.55)&#8221; _builder_version=&#8221;3.17.6&#8243; header_level=&#8221;h3&#8243; \/][\/et_pb_column][\/et_pb_row][\/et_pb_section]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Tubular heat exchangers intended for the smokes cooling in the cogeneration system of a wastewater treatment plant (WWTP).<\/p>\n","protected":false},"author":2,"featured_media":32059,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[47],"tags":[],"class_list":["post-32073","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news"],"_links":{"self":[{"href":"https:\/\/www.sacome.com\/en\/wp-json\/wp\/v2\/posts\/32073"}],"collection":[{"href":"https:\/\/www.sacome.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.sacome.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.sacome.com\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.sacome.com\/en\/wp-json\/wp\/v2\/comments?post=32073"}],"version-history":[{"count":9,"href":"https:\/\/www.sacome.com\/en\/wp-json\/wp\/v2\/posts\/32073\/revisions"}],"predecessor-version":[{"id":32075,"href":"https:\/\/www.sacome.com\/en\/wp-json\/wp\/v2\/posts\/32073\/revisions\/32075"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.sacome.com\/en\/wp-json\/wp\/v2\/media\/32059"}],"wp:attachment":[{"href":"https:\/\/www.sacome.com\/en\/wp-json\/wp\/v2\/media?parent=32073"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.sacome.com\/en\/wp-json\/wp\/v2\/categories?post=32073"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.sacome.com\/en\/wp-json\/wp\/v2\/tags?post=32073"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}