{"id":31954,"date":"2021-04-05T12:53:24","date_gmt":"2021-04-05T10:53:24","guid":{"rendered":"https:\/\/www.sacome.com\/?p=31954"},"modified":"2021-04-05T12:57:50","modified_gmt":"2021-04-05T10:57:50","slug":"condenser-aromas-vacuum-vapours","status":"publish","type":"post","link":"https:\/\/www.sacome.com\/en\/condenser-aromas-vacuum-vapours\/","title":{"rendered":"Condensation of aromas and vapours under vacuum conditions in the  cheese industry"},"content":{"rendered":"<p>[et_pb_section bb_built=&#8221;1&#8243; fullwidth=&#8221;off&#8221; specialty=&#8221;on&#8221; next_background_color=&#8221;#000000&#8243;][et_pb_column type=&#8221;1_2&#8243;][et_pb_image _builder_version=&#8221;3.21&#8243; src=&#8221;https:\/\/www.sacome.com\/wp-content\/uploads\/2021\/04\/Doble-condensador.png&#8221; alt=&#8221;Manufacturing of a double condenser intendended for condensation of aromas and vapours under vacuum conditions.&#8221; title_text=&#8221;Condenser intendended for condensation of aromas and vapours under vacuum conditions.&#8221; max_width=&#8221;85%&#8221; module_alignment=&#8221;center&#8221; \/][\/et_pb_column][et_pb_column type=&#8221;1_2&#8243; specialty_columns=&#8221;3&#8243;][et_pb_row_inner admin_label=&#8221;Fila&#8221;][et_pb_column_inner type=&#8221;4_4&#8243; saved_specialty_column_type=&#8221;1_2&#8243;][et_pb_divider _builder_version=&#8221;3.21&#8243; show_divider=&#8221;off&#8221; height=&#8221;60px&#8221; \/][et_pb_text _builder_version=&#8221;3.21&#8243; border_style=&#8221;solid&#8221;]<\/p>\n<p style=\"text-align: justify;\">One of the most important <strong>cheese producers worldwide<\/strong> (with a portfolio of brands of sliced cheese, spreads, fresh and creamy cheeses) has commissioned <strong><a href=\"https:\/\/www.sacome.com\/en\/about-sacome\/\" rel=\"noopener\" target=\"_blank\">SACOME<\/a><\/strong> to <strong><a href=\"https:\/\/www.sacome.com\/en\/engineering-design\/\" rel=\"noopener\" target=\"_blank\">design<\/a><\/strong> and <strong><a href=\"https:\/\/www.sacome.com\/en\/manufacturing\/\" rel=\"noopener\" target=\"_blank\">manufacturing<\/a><\/strong> a <strong>custom-designed condenser<\/strong> with very particular characteristics.<\/p>\n<p style=\"text-align: justify;\">Our client needed to replace an equipment installed in their facilities. The new <strong>condenser<\/strong> is intended for the <strong>condensation of aromas and vapours under vacuum conditions<\/strong>. The <strong>condenser<\/strong> had to fit into the tight floor space (just over 1 meter) and provide a <strong>higher heat exchange power<\/strong>. On the other hand, our client had <strong>different service fluids<\/strong> (cold water at 8\u00baC and water tower at 20\u00baC). The client wanted to take advantage of both service fluids to <strong>minimize energy consumption<\/strong>.<\/p>\n<p style=\"text-align: justify;\">In order to solve the problem raised, our Technical Department evaluated different alternatives and finally manufactured a <strong>double condenser<\/strong> \u2014 a condenser with a single tube channel (hygienic channel, capable of being cleaned with a CIP solution) and two independent service channels in the same heat exchanger (our <strong><a href=\"https:\/\/www.sacome.com\/en\/sanitary-multitube-heat-exchanger-non-removable-tube-bundle\/\" rel=\"noopener\" target=\"_blank\">S-TFM-I heat exchanger<\/a><\/strong>). This posed some challenges when it came to manufacturing and assembling the equipment. However, and according to our main values as a company, we design and manufacturing a custom solutions to meet our client\u2019s needs.<\/p>\n<p>[\/et_pb_text][\/et_pb_column_inner][\/et_pb_row_inner][\/et_pb_column][\/et_pb_section][et_pb_section bb_built=&#8221;1&#8243; _builder_version=&#8221;3.0.47&#8243; prev_background_color=&#8221;#000000&#8243;][et_pb_row _builder_version=&#8221;3.0.48&#8243; background_size=&#8221;initial&#8221; background_position=&#8221;top_left&#8221; background_repeat=&#8221;repeat&#8221;][et_pb_column type=&#8221;4_4&#8243;][et_pb_text _builder_version=&#8221;3.21&#8243; text_orientation=&#8221;center&#8221;]<\/p>\n<h3>Heat exchangers technical documentation<\/h3>\n<p>[\/et_pb_text][et_pb_blog fullwidth=&#8221;off&#8221; posts_number=&#8221;3&#8243; include_categories=&#8221;33&#8243; show_author=&#8221;off&#8221; show_date=&#8221;off&#8221; show_pagination=&#8221;off&#8221; use_overlay=&#8221;on&#8221; overlay_icon_color=&#8221;rgba(53,120,155,0.55)&#8221; _builder_version=&#8221;3.17.6&#8243; header_level=&#8221;h3&#8243; \/][\/et_pb_column][\/et_pb_row][\/et_pb_section]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Double condenser intendended for condensation of aromas and vapours under vacuum conditions.<\/p>\n","protected":false},"author":2,"featured_media":31948,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[47],"tags":[],"class_list":["post-31954","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news"],"_links":{"self":[{"href":"https:\/\/www.sacome.com\/en\/wp-json\/wp\/v2\/posts\/31954"}],"collection":[{"href":"https:\/\/www.sacome.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.sacome.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.sacome.com\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.sacome.com\/en\/wp-json\/wp\/v2\/comments?post=31954"}],"version-history":[{"count":5,"href":"https:\/\/www.sacome.com\/en\/wp-json\/wp\/v2\/posts\/31954\/revisions"}],"predecessor-version":[{"id":31961,"href":"https:\/\/www.sacome.com\/en\/wp-json\/wp\/v2\/posts\/31954\/revisions\/31961"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.sacome.com\/en\/wp-json\/wp\/v2\/media\/31948"}],"wp:attachment":[{"href":"https:\/\/www.sacome.com\/en\/wp-json\/wp\/v2\/media?parent=31954"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.sacome.com\/en\/wp-json\/wp\/v2\/categories?post=31954"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.sacome.com\/en\/wp-json\/wp\/v2\/tags?post=31954"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}